9
WN 059677 45532 - 11/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Mounting instructions
3.3 Parts included
The parts included are stated on the delivery note. Fixing materials such as dowels
and screws are not included.
3.4 Technical data
Connection voltage: 230V 50Hz+10%/-15%
Fuse supplied by the customer: 10 A
Protection class: IP20
Permissible humidity: 93% relative humidity, non-condensing
Operating temperature:
-20°C to +60°C
Power supply
for external devices
- for mains operation:
- in the event of a mains failure in
battery mode:
24 V DC/max. 2A short-circuit-proof
21–27 V DC/max. 2A short-circuit-proof
Multiport inputs
24 V ±15%
3.5 Closing edge protection
Warning
Only safety sensors with type approval according to EN 16005 may
be used!
3.6 Secondary closing edge protection
If the distance of the opened door leaf to a stationary obstacle (e.g. a wall) is
smaller than 200mm, the secondary closing edge must be protected, for example
with safety sensors or a protective panel.