Parameter Display Value range/
unit
Values
(default = bold)
Explanation
Acceleration in open direction 0–9 7 Adjusting the acceleration in open direction
Opening speed
Standard and CO48 operator
10-90
cm/second
50 Setting the opening speed
Opening speed
FST operator
*)-90
cm/second
65 Setting the opening speed
*) depends on door leaf weight and size
Force limitation in open 5-31
10N
15 Setting the force limitation in opening direction
Hold-open time 0-180
seconds
1 Setting the hold-open time
Night/bank hold-open time 0-180
seconds
0 Setting the hold-open time for night/bank
Closing speed 10-90
cm/second
25 Setting the closing speed
Force limitation in closed position 5-31
10N
15 Setting the force limitation in the closing direction
Sensitivity of the collision detection
when the threshold value is
undershot
0-2 0 Low sensitivity
1 Medium sensitivity
2 High sensitivity
Sensitivity of the collision detection
when the threshold value is exceeded
0-2 0 Low sensitivity
1 Medium sensitivity
2 High sensitivity
Locking force 0-9
10N