70
WN 059677 45532 - 11/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Mounting instructions
Parameter Display Value range/
unit
Values
(default = bold)
Explanation
Factory settings setup 1-3 1 Reset configuration and travel parameters
2 Level 1 and special functions
3 Level 2 and passwords, operating data, CAN and
historical data
CAN reset 0-1 0 Activation
1 Set value for execution to 1
Sensors’ parameter transfers
If a sensor is replaced, the data
stored in the control unit can be
transferred.
0–9 0 -
1 Sensor 1 - Write parameters to sensor
2 Sensor 2 - Write parameters to sensor
3 Sensor 3 - Write parameters to sensor
4 Sensor 4 - Write parameters to sensor
5 Sensor 5 - Write parameters to sensor
6 Sensor 6 - Write parameters to sensor
7 Sensor 7 - Write parameters to sensor
8 Sensor 8 - Write parameters to sensor
9 Write all parameters from the sensor to the
operator control unit
Door pilot reset 0-1 0 Activation
1 Set value for execution to 1
Door weight Shows the taught-in door weight in kg
Maintenance date via the control
panel
0-1 0 Activation
1 Maintenance is reset
Delete error memories
0-1 0
1 Set value for deletion to 1
Service mode 0-2 0 Not active
1 Service Mode 1
2 Service Mode 2