Instructions for Use Oxylog 2000 plus SW 1.n 33
Assembly
Installing the battery
1 Insert a fully charged battery into the battery
compartment.
2 Attach the connector at the bottom.
3 Turn the cover upwards.
4 Tighten the screw.
External power supply with
DC/DC converter
The DC/DC converter must be used to connect the
Oxylog 2000 plus to on-board supplies of different
voltages (12 V, 24 V, 28 V DC).
The voltage of the on-board supply may fluctuate,
depending on the amount of power required. The
supply voltage may fall below or exceed the range
permitted by the Oxylog 2000 plus. The on-board
voltage is converted into a constant DC voltage of
approximately 19 V DC by the DC/DC converter:
When connected to an external power supply
(e.g. the on-board power supply of the vehicle),
the ventilator must always be connected via the
DC/DC converter, refer to the "List of Accesso-
ries" on page 123 for additional information.
1 Plug the large connector (A) of the DC/DC con-
verter into the on-board supply.
2 Plug the small connector (B) into the DC nozzle
of the Oxylog 2000 plus.
3 When the Oxylog 2000 plus is connected to an
external supply, the indicator
N (C) lights up
and displays the internal battery status.
External power supply from mains
power
(AC/DC Power pack)
WARNING
The Oxylog 2000 plus will interrupt ventilation
when the battery is replaced while the device
is switched on and the external power supply
is not connected. Ventilation will resume with
the last values settings approximately 3 sec-
onds after inserting the battery.
NOTE
It is recommended to use fully charged internal
batteries.
WARNING
Use only a specified DC/DC converter.
Otherwise the device can malfunction.
Refer to the "List of Accessories" on page 108
for additional information.
016
WARNING
Use only a specified AC/DC power pack
equipped with a correct mains plug.
Otherwise the device can malfunction.
Refer to the "List of Accessories" on page 108
for additional information.
WARNING
The AC/DC power pack may not be used
outdoors.
Risk of electric shock or equipment damage.