Error Info/Description Remedy
2256 · Step motor Y-axis
excess temperature
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
Control defective
· Eliminate the blocking/rough
running
· Exchange step motor Y-axis
· Exchange the control
2262 · Step motor Y-axis
IDMA Autoincrement
·Malfunction
·Switchthemachineoff
and on again
2301 · Step motor Z-axis
timeout reference
· Cable to the reference switch
faulty
·Reference switch defective
· Exchange the cable
· Exchange the reference switch
2302 · Step motor Z-axis
Current supply fault
· Step motor Z-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Eliminate the blocking
· Check/
exchange the encoder cable
· Exchange step motor Z-axis
2352 · Step motor Z-axis
excess current
· Step motor Z-axis defective
· Control defective
· Exchange step motor Z-axis
· Exchange the control
2353 · Step motor Z-axis
excess voltage
· Too high mains voltage
· Check the mains voltage
2355 · Step motor Z-axis
overcharge
· Step motor Z-axis
blocked/moves too heavy
· Step motor Z-axis defective
· Control defective
· Eliminate the blocking/rough
running
· Exchange step motor Z-axis
· Exchange the control
2356 · Step motor Z-axis
excess temperature
· Step motor Z-axis
moves too heavy
· Step motor Z-axis defective
· Control defective
· Eliminate the rough running
· Exchange step motor Z-axis
· Exchange the control
2362 · Step motor Z-axis
IDMA Autoincrement
· Malfunction
· Switch the machine off and on
again
108