EasyManua.ls Logo

DURKOPP ADLER 580 - Page 113

DURKOPP ADLER 580
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Info/Description Remedy
2911
-
2914
· Step motor fault
· Internal fault
· Switch the machine off and on
again.
· Software update
· Information to DA-Service
3100
-
3103
· Machine voltage fault
· Short-term mains voltage dip
· Check the mains voltage and
stabilize, if necessary
3107 · Machine temperature
· Ventilation openings
closed
· Ventilation grids soiled
· Too high ambient temperature
· Check the ventilation openings
· Clean the ventilation grids
· Let the machine cool down
3221
-
3222
· Machine thread tension
regulator
· Internal fault
· Switch the machine off and on
again
· Software update
· Information to DA-Service
3300
-
3724
· Fault in the machine control
· Internal fault
· Switch the machine off and on
again
· Software update
· Information to DA-Service
4460
-
4468
· Operation BF-4
· Malfunction
· Switch the machine off and on
again
· Information to DA-Service
4500
-
4503
· Menu system fault
· Internal fault
· Switch the machine off and on
again
· Software update
· Information to DA-Service
6000
-
6299
·Driverfault
· Internal fault
· Switch the machine off and on
again
· Software update
· Information to DA-Service
6351
-
6354
· I²C fault
· Control defective
· Exchange the control
6400
-
6999
·Driverfault
· Internal fault
· Switch the machine off and on
again
· Software update
· Information to DA-Service
7451
7453
7454
· Communication
test interface
· Internal fault
· Switch the machine off and on
again
3
109

Table of Contents