Programming
Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017 187
Reading data from the USB key to the system
The display switches to Data transfer from USB.
Fig. 157: Data transfer from USB (1)
To read data from the USB key to the system:
1. Select which data you wish to store in the control:
Current seam program
All seam programs
All seam programs and sequences
Global parameters
Machine config.
2. Press the button to confirm.
The software checks the USB key.
The selected option is written to the OP7000.
NOTICE
Property damage may occur!
The machine will not work if you load data from a wrong class.
Loading data from an incorrect class will generate irregular error
messages.
Check the class before loading Machine configuration or All data.
After loading Machine configuration or All data, check the class and
the configuration in the Machine configuration menu.