Operation
Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017 33
Fig. 23: Swiveling down the machine head (2)
To swivel the machine head back down (shown by the example of the
745-35-10 A):
1. Hold the machine head in the head cover area (2).
2. Release the latch (5).
3. Swivel down the machine head carefully.
4. Insert the fabric sliding plate (4).
5. Swivel the locking lever (3) down.
6. Swivel down the folding station and latch it using the locking lever (3)
( p. 18).
7. Replace and re-engage the hood (1).
4.13 Remaining thread monitor
The remaining thread monitor together with the infrared reflected light bar-
riers (1) and (2) monitors the left and the right bobbin thread reel.
Fig. 24: Remaining thread monitor
(4) - Fabric sliding plate (5) - Latch
④⑤
(1) - Light barrier 1
(2) - Light barrier 2
(3) - Reflecting surface
②③