Operation
20 Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017
4.5 Changing needles
Fig. 8: Changing needles
To change the needles:
1. Swivel the folding station out of the way ( p. 18).
The needles are freely accessible.
2. Loosen the screws (3) and remove the needles from the needle
holders (1).
3. Insert the new needle into the hole of the needle holder (1) until it
reaches the stop.
CAUTION
Risk of injury from sharp parts!
Punctures or cutting.
Only change needles with the main switch turned
off.
When changing the needles, NEVER reach into the
area of the middle knife.
NOTICE
Property damage may occur!
When switching to needles with a different thickness, the needle can
be damaged by the hook.
Readjust the needle guard at the hook.
(1) - Needle holder
(2) - Middle knife
(3) - Screws
(4) - Needle groove left needle
(5) - Needle groove right needle