242 Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017
9703 Folder not slanted Correct folder setting
9704 Folder not on the pipe table Correct folder setting
9707 Scissors not down Correct the scissors setting
9708 Scissors not up Correct the scissors setting
9709 Downholder not up Correct the downholder setting
9720 Error during flap scanning with
light barrier
Check reflecting foil
Check alignment of the light
barriers
9721 Flap has been positioned in front
of the front positioning point
Insert the flap correctly
9722 Flap projects beyond the
maximum sewing area (behind
the rear positioning point)
Check flap size
Insert the flap correctly
9723 Fluff at the flap beginning Insert flaps with smooth edges
Check reflecting foil
9725 Flap angle too great
Flap too small
Check flap angle
Check alignment of the light
barriers
Adjust seam parameters
(seam securement possibly too
long for small flaps)
9726 Flap too large
Reflecting foil dirty/damaged
Check flap size
Check reflecting foil
9727 Stop section insufficient for the
flap angle
Reduce the insertion speed
p. 125
9728 Flap too small Check the flap size; insert a larger
flap
9730 Corner knife cut impossible Increment the pocket length
Use additional equipment short
pockets
9800 Middle knife not ready for use Check cable
9810 Smoother not ready for use Check cable
Error code Symbol Meaning Remedial action