EasyManua.ls Logo

EDAN iM3 - Service Manual

EDAN iM3
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EDAN Agile PLM Electronic Signature Information
--Signatures related to this document and performed in EDAN Agile PLM.
文件名称(Document Name):iM3 维修手册_英文
文件编号(Number):01.54.457834
版本(Version):1.1
产品型号(Product Model):iM3
项目编码(Project Code):00004I002
签批信息(Signature):
作者(Originator) : 陈 艳娟 (chenyanjuan) 2018-02-07 10:15:49
审核人(Reviewers) : 程 亮 (chengliang) 2018-02-07 11:33:42
审核人(Reviewers) : 史 洪华 (shihonghua) 2018-02-07 11:28:34
审核人(Reviewers) : 韦 华彪 (weihuabiao) 2018-02-07 15:36:37
审核人(Reviewers) : 陈 良款 (chenliangkuan) 2018-02-07 14:08:44
批准人(Approvers) : 夏 欢欢 (xiahuanhuan) 2018-02-24 13:16:16
批准人(Approvers) : 陈 浩杰 (chenhaojie) 2018-02-23 15:21:15
版权©深圳市理邦精密仪器股份有限公司 (Copyright©Edan Instrument,Inc.)

Table of Contents

Other manuals for EDAN iM3

Questions and Answers

  • H
    Holly SanchezSep 15, 2025
    What should I do if the fuses burn out when a specific part is connected to my EDAN Medical Equipment?
    • K
      kevinjonesSep 15, 2025
      If the fuses burn out when a certain part is connected to your EDAN Medical Equipment, it indicates a short circuit of the specific part. Replace the specific part.
  • D
    Diane Bautista MDAug 25, 2025
    How to fix an EDAN Medical Equipment LCD with no display and the power indicator is off?
    • J
      James JimenezAug 25, 2025
      If the LCD on your EDAN Medical Equipment has no display and the power indicator is off, the issue could be due to fuse damage (if applicable), power board damage, or component short-circuits. Try replacing the fuse, or the power board. Another solution is to anchor the short-circuited component.
  • B
    bschroederAug 25, 2025
    Why does the touch screen on my EDAN Medical Equipment not respond?
    • L
      Lindsay WhiteAug 26, 2025
      If the touch screen on your EDAN Medical Equipment is unresponsive, it could be due to a bad connection of the touch screen wire, touch screen damage, or main control board failure. Check and reconnect the connecting wire. If that doesn't work, consider replacing the touch screen or main control board.
  • P
    Philip BrownAug 26, 2025
    Why does my EDAN Medical Equipment crash unexpectedly?
    • B
      Barbara DavisAug 27, 2025
      Unexpected crashes in your EDAN Medical Equipment can be caused by instantaneous intensive network interference, poor power board performance, poor main control board performance, or bad connections of the power board or main control board. Check the power supply and grounding system. You may need to replace the power board or main control board, or replace or repair connectors.
  • D
    Douglas WarnerSep 16, 2025
    Why are no audio or visual alarms activated on my EDAN Medical Equipment?
    • M
      mcmillandonaldSep 17, 2025
      If no audio or visual alarms are activated on your EDAN Medical Equipment, it indicates a program failure. Update the software.
  • K
    Katherine BrownSep 23, 2025
    Why is there no TEMP value on my EDAN Medical Equipment (T2A, F3000 and TH module)?
    • K
      Kyle JonesSep 23, 2025
      If there is no TEMP value on your EDAN Medical Equipment (for T2A, F3000 and TH module), it could be due to a bad connection of the wire between the TEMP module (T2A, F3000 and TH module) and the monitor, damage to the TEMP module, damage to the TEMP probe, or damage to the main control board. Check the connection and reconnect the connecting wire. If the malfunction continues, replace the connecting wire, the TEMP module, the TEMP probe, or the main control board.
  • K
    Karen ClaytonSep 8, 2025
    Why is the trace blurred, tilted, or blank on the recording paper of my EDAN Medical Equipment?
    • C
      Christopher SchmidtSep 8, 2025
      If the trace on the recording paper of your EDAN Medical Equipment is blurred, tilts, or is blank, it may be due to inexact loading of the recording paper, the two screw nuts on the print head are not adjusted to balance, or recording head failure. Load the recording paper exactly. Adjust the screw nuts. If the issue continues, replace the recording head.
  • M
    Mary HallSep 9, 2025
    Why do the fuses burn out when I switch on my EDAN Medical Equipment?
    • N
      Nancy NelsonSep 9, 2025
      If the fuses burn out when you switch on your EDAN Medical Equipment, this indicates a short circuit of the power or other parts. Switch on the monitor for further check.
  • L
    Laura TuckerSep 2, 2025
    What causes disabled operation or measurement functions on EDAN Medical Equipment?
    • J
      Jonathan JohnsonSep 2, 2025
      If an operation or measurement function is disabled on your EDAN Medical Equipment, it could be due to main control board or corresponding component damage. Examine the main control board and the corresponding components.
  • J
    Jason ReedAug 31, 2025
    What to do if the rotary knob on my EDAN Medical Equipment isn't working?
    • H
      hannahdavisSep 1, 2025
      If turning the rotary knob on your EDAN Medical Equipment produces no reaction, it could be due to a bad connection of the wire between the rotary knob and main control board, rotary knob switch damage, or main control board failure. Check the connection and reconnect the connecting wire. If that doesn't resolve the issue, replace the rotary knob or the main control board.

Summary

About this Manual

Statement

Explains the manual's purpose and user responsibilities regarding copyright and intellectual property.

Responsibility of the Manufacturer

Outlines EDAN's responsibility for equipment safety and performance under specific conditions.

Terms Used in this Manual

Safety Terminology Definitions

Defines key safety terms like WARNING, CAUTION, and NOTE used throughout the manual.

Chapter 1 Warranty and Service

Standard Service and Warranty Terms

Details EDAN's one-year warranty, service quality, and limitations.

Warranty Service Procedure

Outlines the steps for submitting a warranty claim, including form completion and part return.

Contact Information

Provides EDAN's contact details for inquiries about maintenance, specifications, or malfunctions.

Chapter 2 Safety Guidance

Introduction to Safety Guidance

Introduces the service manual as a guide for maintenance and corrective procedures for the iM3 monitor.

General Information and Safety Standards

Provides classification information for the iM3 monitor based on international safety standards.

General Safety Precautions

Lists essential precautions for operating and servicing the monitor to prevent injury.

Explanation of Monitor Symbols

Explains various symbols used on the iM3 monitor and their meanings.

Chapter 3 Installation

Environment Requirements for Installation

Specifies the required temperature, humidity, and altitude conditions for operating and storing the monitor.

Electrical Requirements for Installation

Lists the electrical specifications, including operating voltage, frequency, input current, and fuse type.

Installation Safety Requirements

Details critical safety requirements for power outlets and connections to prevent electrical hazards.

Monitor Installation Methods

Provides instructions for physically placing the monitor on a flat surface or mounting it.

Connecting to AC Power Supply

Explains how to properly connect the monitor to the AC power source using the provided cable.

Chapter 4 Test and Maintenance

Routine Test Procedures

Outlines general checks, including visual inspection and power-on tests, to ensure the monitor is functioning correctly.

Functional and Accuracy Tests

Details procedures for testing the functional performance and accuracy of the monitor's measurements.

Safety Test Procedures

Describes procedures for performing electrical safety tests to ensure patient and equipment safety.

General Maintenance Guidelines

Provides guidance on general cleaning and maintenance procedures for the monitor.

Chapter 5 System Configuration

Factory Maintenance and Updates

Details how service engineers can access factory maintenance settings and perform various updates or tests.

Demonstration Mode Activation

Explains how to activate the monitor's demonstration mode for showcasing its features.

Default and User Configurations

Guides users on selecting or saving factory or custom configurations for the monitor.

Network Setup Configuration

Outlines the steps for configuring wired or Wi-Fi network settings, including IP address assignment.

System Time Configuration

Describes how to set and synchronize the monitor's system time and date.

Chapter 6 Principle Introduction

System Principle Block Diagram

Presents a block diagram illustrating the system architecture and component connections of the iM3 monitor.

Monitor Interface Description

Identifies and describes the various physical ports and connectors on the iM3 monitor.

Chapter 7 Troubleshooting

Machine Failures Troubleshooting

Lists common machine failures, their possible causes, and recommended solutions for the iM3 monitor.

Display Failures Troubleshooting

Details issues related to the monitor's display, including character display and screen blackouts, with troubleshooting steps.

Operation Failures Troubleshooting

Covers problems with user interface elements like buttons, touch screen, and rotary knob, providing solutions.

Recorder Failures Troubleshooting

Addresses issues with the printer, such as no paper output, blurred traces, or paper jams.

Network Failures Troubleshooting

Lists problems related to network connectivity, including inability to connect to Wi-Fi or wired networks.

Power Board Failures Troubleshooting

Explains troubleshooting steps for power-related issues, such as blown fuses.

Alarm Failures Troubleshooting

Describes issues with audio or visual alarms not activating and provides solutions.

Parameter Failures Troubleshooting

Covers problems with specific parameter measurements like NIBP and SpO2, including communication stops and inaccuracies.

Chapter 8 Disassembling the Monitor

Required Tools for Disassembly

Lists the necessary tools for disassembling and servicing the iM3 monitor.

Main Unit Disassembly Procedure

Provides a step-by-step guide to disassembling the main components of the iM3 monitor.

Front Housing Assembly Disassembly

Details the process of disassembling the front housing of the iM3 monitor to access internal components.

Rear Housing Assembly Disassembly

Guides the disassembly of the rear housing of the iM3 monitor.

Middle Frame Assembly Disassembly

Details the process of removing the middle frame assembly from the iM3 monitor.

Plug-in Module Disassembly

Outlines the disassembly of various plug-in modules for the iM3 monitor.

Chapter 9 Replaceable Parts

EDAN iM3 Specifications

General IconGeneral
SpO2Yes
NIBPYes
TemperatureYes
RespirationYes
Pulse RateYes
Display Size8.4 inches
BatteryRechargeable lithium-ion
Battery LifeUp to 4 hours
Storage Temperature-20 ~ 60 ℃