EDAN Agile PLM Electronic Signature Information
--Signatures related to this document and performed in EDAN Agile PLM.
文件名称(Document Name):iM3 维修手册_英文
文件编号(Number):01.54.457834
版本(Version):1.1
产品型号(Product Model):iM3
项目编码(Project Code):00004I002
签批信息(Signature):
作者(Originator) : 陈 艳娟 (chenyanjuan) 2018-02-07 10:15:49
审核人(Reviewers) : 程 亮 (chengliang) 2018-02-07 11:33:42
审核人(Reviewers) : 史 洪华 (shihonghua) 2018-02-07 11:28:34
审核人(Reviewers) : 韦 华彪 (weihuabiao) 2018-02-07 15:36:37
审核人(Reviewers) : 陈 良款 (chenliangkuan) 2018-02-07 14:08:44
批准人(Approvers) : 夏 欢欢 (xiahuanhuan) 2018-02-24 13:16:16
批准人(Approvers) : 陈 浩杰 (chenhaojie) 2018-02-23 15:21:15
版权©深圳市理邦精密仪器股份有限公司 (Copyright©Edan Instrument,Inc.)

Table of Contents

Other manuals for EDAN iM3

Questions and Answers

  • M
    markgibsonSep 3, 2025
    Why isn't the built-in scanner on my EDAN Medical Equipment emitting light or scanning?
    • L
      Luis SteeleSep 3, 2025
      If the built-in scanner on your EDAN Medical Equipment isn't emitting light or is unable to scan, it could be due to a bad connection of the wire between the scanner and parameter board, scanner malfunction leading to communication failure with the main control board, or main control board malfunction leading to communication failure with the scanner. Check the connection and reconnect the connecting wire. If the issue persists, replace the scanner or the main control board.
  • L
    Laura TuckerSep 2, 2025
    What causes disabled operation or measurement functions on EDAN Medical Equipment?
    • J
      Jonathan JohnsonSep 2, 2025
      If an operation or measurement function is disabled on your EDAN Medical Equipment, it could be due to main control board or corresponding component damage. Examine the main control board and the corresponding components.
  • R
    Robert TravisSep 1, 2025
    Why is there no sound or a hoarse sound coming from the EDAN Medical Equipment speaker?
    • W
      William RamosSep 1, 2025
      If the speaker on your EDAN Medical Equipment has a hoarse sound or no sound at all, it could indicate a malfunction in the audio subassembly of the main control board or a malfunction in the speaker or connecting wire. Consider replacing the main control board, or replacing the speaker or connecting wire.
  • J
    Jason ReedAug 31, 2025
    What to do if the rotary knob on my EDAN Medical Equipment isn't working?
    • H
      hannahdavisSep 1, 2025
      If turning the rotary knob on your EDAN Medical Equipment produces no reaction, it could be due to a bad connection of the wire between the rotary knob and main control board, rotary knob switch damage, or main control board failure. Check the connection and reconnect the connecting wire. If that doesn't resolve the issue, replace the rotary knob or the main control board.
  • B
    Benjamin GriffinAug 30, 2025
    Why can't my EDAN Medical Equipment connect to Wi-Fi?
    • C
      cynthiaholderAug 30, 2025
      If your EDAN Medical Equipment is unable to connect to Wi-Fi, it could be due to the antenna not being connected to the Wi-Fi board, a Wi-Fi board failure, or a main control board failure. Check and reconnect the connecting wire. If the issue persists, replace the Wi-Fi board or the main control board.
  • R
    Richard SpenceAug 30, 2025
    What should I do if my EDAN Medical Equipment doesn't recognize a USB flash disk?
    • J
      Jacqueline AlexanderAug 30, 2025
      If your EDAN Medical Equipment shows no reaction when you insert a USB flash disk, the disk itself might be damaged, or there could be a parameter board failure or main control board failure. Try another USB flash disk. If it still doesn't work, consider replacing the parameter board or the main control board.
  • T
    Troy JacksonAug 29, 2025
    How do I fix network connection issues with my EDAN Medical Equipment?
    • D
      Donna StewartAug 29, 2025
      If you're unable to connect your EDAN Medical Equipment to the network, the problem might be a malfunction in the network linking wire, a Network Bed No. conflict, or a main control board failure. Check and repair the network linking wire or the HUB. Try to change Bed No.. If problems persist, replace the main control board.
  • E
    Elizabeth SilvaAug 28, 2025
    Why are wrong characters displayed on my EDAN Medical Equipment screen?
    • L
      Latoya McbrideAug 28, 2025
      If your EDAN Medical Equipment displays wrong characters, it could be due to a bad connection of the LCD display screen wire or LCD display screen failure. Check the connection wire of LCD connection and main control board. If the issue persists, replace the LCD screen.
  • M
    mikayla67Aug 27, 2025
    How to troubleshoot disabled buttons on EDAN Medical Equipment?
    • J
      James MarshAug 27, 2025
      If the buttons on your EDAN Medical Equipment are disabled, the cause may be button damage or main control board damage. You may need to replace the button or the main control board.
  • P
    Philip BrownAug 26, 2025
    Why does my EDAN Medical Equipment crash unexpectedly?
    • B
      Barbara DavisAug 27, 2025
      Unexpected crashes in your EDAN Medical Equipment can be caused by instantaneous intensive network interference, poor power board performance, poor main control board performance, or bad connections of the power board or main control board. Check the power supply and grounding system. You may need to replace the power board or main control board, or replace or repair connectors.

Summary

About this Manual

Statement

Explains the manual's purpose and user responsibilities regarding copyright and intellectual property.

Responsibility of the Manufacturer

Outlines EDAN's responsibility for equipment safety and performance under specific conditions.

Terms Used in this Manual

Safety Terminology Definitions

Defines key safety terms like WARNING, CAUTION, and NOTE used throughout the manual.

Chapter 1 Warranty and Service

Standard Service and Warranty Terms

Details EDAN's one-year warranty, service quality, and limitations.

Warranty Service Procedure

Outlines the steps for submitting a warranty claim, including form completion and part return.

Contact Information

Provides EDAN's contact details for inquiries about maintenance, specifications, or malfunctions.

Chapter 2 Safety Guidance

Introduction to Safety Guidance

Introduces the service manual as a guide for maintenance and corrective procedures for the iM3 monitor.

General Information and Safety Standards

Provides classification information for the iM3 monitor based on international safety standards.

General Safety Precautions

Lists essential precautions for operating and servicing the monitor to prevent injury.

Explanation of Monitor Symbols

Explains various symbols used on the iM3 monitor and their meanings.

Chapter 3 Installation

Environment Requirements for Installation

Specifies the required temperature, humidity, and altitude conditions for operating and storing the monitor.

Electrical Requirements for Installation

Lists the electrical specifications, including operating voltage, frequency, input current, and fuse type.

Installation Safety Requirements

Details critical safety requirements for power outlets and connections to prevent electrical hazards.

Monitor Installation Methods

Provides instructions for physically placing the monitor on a flat surface or mounting it.

Connecting to AC Power Supply

Explains how to properly connect the monitor to the AC power source using the provided cable.

Chapter 4 Test and Maintenance

Routine Test Procedures

Outlines general checks, including visual inspection and power-on tests, to ensure the monitor is functioning correctly.

Functional and Accuracy Tests

Details procedures for testing the functional performance and accuracy of the monitor's measurements.

Safety Test Procedures

Describes procedures for performing electrical safety tests to ensure patient and equipment safety.

General Maintenance Guidelines

Provides guidance on general cleaning and maintenance procedures for the monitor.

Chapter 5 System Configuration

Factory Maintenance and Updates

Details how service engineers can access factory maintenance settings and perform various updates or tests.

Demonstration Mode Activation

Explains how to activate the monitor's demonstration mode for showcasing its features.

Default and User Configurations

Guides users on selecting or saving factory or custom configurations for the monitor.

Network Setup Configuration

Outlines the steps for configuring wired or Wi-Fi network settings, including IP address assignment.

System Time Configuration

Describes how to set and synchronize the monitor's system time and date.

Chapter 6 Principle Introduction

System Principle Block Diagram

Presents a block diagram illustrating the system architecture and component connections of the iM3 monitor.

Monitor Interface Description

Identifies and describes the various physical ports and connectors on the iM3 monitor.

Chapter 7 Troubleshooting

Machine Failures Troubleshooting

Lists common machine failures, their possible causes, and recommended solutions for the iM3 monitor.

Display Failures Troubleshooting

Details issues related to the monitor's display, including character display and screen blackouts, with troubleshooting steps.

Operation Failures Troubleshooting

Covers problems with user interface elements like buttons, touch screen, and rotary knob, providing solutions.

Recorder Failures Troubleshooting

Addresses issues with the printer, such as no paper output, blurred traces, or paper jams.

Network Failures Troubleshooting

Lists problems related to network connectivity, including inability to connect to Wi-Fi or wired networks.

Power Board Failures Troubleshooting

Explains troubleshooting steps for power-related issues, such as blown fuses.

Alarm Failures Troubleshooting

Describes issues with audio or visual alarms not activating and provides solutions.

Parameter Failures Troubleshooting

Covers problems with specific parameter measurements like NIBP and SpO2, including communication stops and inaccuracies.

Chapter 8 Disassembling the Monitor

Required Tools for Disassembly

Lists the necessary tools for disassembling and servicing the iM3 monitor.

Main Unit Disassembly Procedure

Provides a step-by-step guide to disassembling the main components of the iM3 monitor.

Front Housing Assembly Disassembly

Details the process of disassembling the front housing of the iM3 monitor to access internal components.

Rear Housing Assembly Disassembly

Guides the disassembly of the rear housing of the iM3 monitor.

Middle Frame Assembly Disassembly

Details the process of removing the middle frame assembly from the iM3 monitor.

Plug-in Module Disassembly

Outlines the disassembly of various plug-in modules for the iM3 monitor.

Chapter 9 Replaceable Parts

EDAN iM3 Specifications

General IconGeneral
SpO2Yes
NIBPYes
TemperatureYes
RespirationYes
Pulse RateYes
Display Size8.4 inches
BatteryRechargeable lithium-ion
Battery LifeUp to 4 hours
Storage Temperature-20 ~ 60 ℃

Related product manuals