EasyManua.ls Logo

EDAN iM3 - Service Manual

EDAN iM3
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EDAN Agile PLM Electronic Signature Information
--Signatures related to this document and performed in EDAN Agile PLM.
文件名称(Document Name):iM3 维修手册_英文
文件编号(Number):01.54.457834
版本(Version):1.1
产品型号(Product Model):iM3
项目编码(Project Code):00004I002
签批信息(Signature):
作者(Originator) : 陈 艳娟 (chenyanjuan) 2018-02-07 10:15:49
审核人(Reviewers) : 程 亮 (chengliang) 2018-02-07 11:33:42
审核人(Reviewers) : 史 洪华 (shihonghua) 2018-02-07 11:28:34
审核人(Reviewers) : 韦 华彪 (weihuabiao) 2018-02-07 15:36:37
审核人(Reviewers) : 陈 良款 (chenliangkuan) 2018-02-07 14:08:44
批准人(Approvers) : 夏 欢欢 (xiahuanhuan) 2018-02-24 13:16:16
批准人(Approvers) : 陈 浩杰 (chenhaojie) 2018-02-23 15:21:15
版权©深圳市理邦精密仪器股份有限公司 (Copyright©Edan Instrument,Inc.)

Table of Contents

Other manuals for EDAN iM3

Questions and Answers

  • G
    garciakarenSep 13, 2025
    Why does NIBP function communication stop on my EDAN Medical Equipment?
    • T
      tylershortSep 13, 2025
      If NIBP function communication stops on your EDAN Medical Equipment, it could be due to a bad connection between the parameter board and main control board, NIBP module function failure of the parameter board, or main control board failure. Check the connection between boards. If the problem persists, replace the parameter board or the main control board.
  • K
    Karen DownsSep 12, 2025
    Why is there no audio alarm on my EDAN Medical Equipment?
    • C
      Caleb DavisSep 12, 2025
      If no audio alarm is activated on your EDAN Medical Equipment, it might be because the audio alarm is temporarily disabled, or the speaker and its connecting wire have failed. Switch on the audio alarm. If the issue persists, replace the speaker or the wire.
  • M
    Mr. James MooreSep 12, 2025
    What if the fuses in my EDAN Medical Equipment keep burning out after disconnecting all loads?
    • S
      Stephanie ThomasSep 12, 2025
      If the fuses in your EDAN Medical Equipment continue to burn out even after disconnecting all loads, it suggests a power board failure. Replace the power board.
  • S
    smonroeSep 10, 2025
    What causes great errors in NIBP measurement in EDAN Medical Equipment?
    • M
      Matthew FuentesSep 10, 2025
      Significant errors in NIBP measurements on your EDAN Medical Equipment can be caused by using a cuff size that doesn't fit the patient or parameter board failure. Use the cuff of appropriate size. If the problem persists, replace the parameter board.
  • M
    Mary HallSep 9, 2025
    Why do the fuses burn out when I switch on my EDAN Medical Equipment?
    • N
      Nancy NelsonSep 9, 2025
      If the fuses burn out when you switch on your EDAN Medical Equipment, this indicates a short circuit of the power or other parts. Switch on the monitor for further check.
  • K
    Karen ClaytonSep 8, 2025
    Why is the trace blurred, tilted, or blank on the recording paper of my EDAN Medical Equipment?
    • C
      Christopher SchmidtSep 8, 2025
      If the trace on the recording paper of your EDAN Medical Equipment is blurred, tilts, or is blank, it may be due to inexact loading of the recording paper, the two screw nuts on the print head are not adjusted to balance, or recording head failure. Load the recording paper exactly. Adjust the screw nuts. If the issue continues, replace the recording head.
  • J
    James SwansonAug 23, 2025
    What to do if my EDAN Medical Equipment shuts down suddenly?
    • T
      Terry PattersonAug 23, 2025
      If your EDAN Medical Equipment shuts down suddenly, especially if it's battery-powered, the battery may be low; connect it to AC power to charge. Other potential causes include a high voltage strike (like lightning), a bad power input connection, power failure, or main control board failure. Check the power supply, grounding system, and power input. If necessary, replace the power supply or main control board.
  • K
    kerri08Sep 6, 2025
    What to do if my EDAN Medical Equipment doesn't print when I press Record?
    • H
      Herbert Ellis Jr.Sep 6, 2025
      If your EDAN Medical Equipment doesn't print when you press Record, possible causes include: no paper in the drawer, the drawer is open, paper is jammed, recording control board failure, recorder connection failure, gear box/ gear failure, main control board failure, or the incorrect printer module category was not selected. Load paper and close the drawer. Check all the connections. Replace the recording control board, the gear box or the gear, or the main control board. Set in Factory Maintain and turn on the printer mode, selecting U for Unicode printers or E otherwise.
  • M
    mturnerSep 5, 2025
    Why does my EDAN Medical Equipment show 'out of paper' when there is paper?
    • A
      alex31Sep 5, 2025
      If your EDAN Medical Equipment displays an 'out of paper' alarm despite paper being in the drawer, it could be because the detector of recording paper is contaminated, the detector of recording paper has failed, or the drawer is not fastened up. Clean the detector of recording paper. If that doesn't work, replace the detector of recording paper or fasten up the drawer.
  • N
    Nicole ThompsonSep 4, 2025
    What causes intermittent waveform display on EDAN Medical Equipment?
    • D
      davisalexisSep 4, 2025
      Intermittent waveform display on your EDAN Medical Equipment, while characters are normal, suggests a data communication error between the main control board and parameter module. Replace the main control board or parameter module based on the error prompt.

Summary

About this Manual

Statement

Explains the manual's purpose and user responsibilities regarding copyright and intellectual property.

Responsibility of the Manufacturer

Outlines EDAN's responsibility for equipment safety and performance under specific conditions.

Terms Used in this Manual

Safety Terminology Definitions

Defines key safety terms like WARNING, CAUTION, and NOTE used throughout the manual.

Chapter 1 Warranty and Service

Standard Service and Warranty Terms

Details EDAN's one-year warranty, service quality, and limitations.

Warranty Service Procedure

Outlines the steps for submitting a warranty claim, including form completion and part return.

Contact Information

Provides EDAN's contact details for inquiries about maintenance, specifications, or malfunctions.

Chapter 2 Safety Guidance

Introduction to Safety Guidance

Introduces the service manual as a guide for maintenance and corrective procedures for the iM3 monitor.

General Information and Safety Standards

Provides classification information for the iM3 monitor based on international safety standards.

General Safety Precautions

Lists essential precautions for operating and servicing the monitor to prevent injury.

Explanation of Monitor Symbols

Explains various symbols used on the iM3 monitor and their meanings.

Chapter 3 Installation

Environment Requirements for Installation

Specifies the required temperature, humidity, and altitude conditions for operating and storing the monitor.

Electrical Requirements for Installation

Lists the electrical specifications, including operating voltage, frequency, input current, and fuse type.

Installation Safety Requirements

Details critical safety requirements for power outlets and connections to prevent electrical hazards.

Monitor Installation Methods

Provides instructions for physically placing the monitor on a flat surface or mounting it.

Connecting to AC Power Supply

Explains how to properly connect the monitor to the AC power source using the provided cable.

Chapter 4 Test and Maintenance

Routine Test Procedures

Outlines general checks, including visual inspection and power-on tests, to ensure the monitor is functioning correctly.

Functional and Accuracy Tests

Details procedures for testing the functional performance and accuracy of the monitor's measurements.

Safety Test Procedures

Describes procedures for performing electrical safety tests to ensure patient and equipment safety.

General Maintenance Guidelines

Provides guidance on general cleaning and maintenance procedures for the monitor.

Chapter 5 System Configuration

Factory Maintenance and Updates

Details how service engineers can access factory maintenance settings and perform various updates or tests.

Demonstration Mode Activation

Explains how to activate the monitor's demonstration mode for showcasing its features.

Default and User Configurations

Guides users on selecting or saving factory or custom configurations for the monitor.

Network Setup Configuration

Outlines the steps for configuring wired or Wi-Fi network settings, including IP address assignment.

System Time Configuration

Describes how to set and synchronize the monitor's system time and date.

Chapter 6 Principle Introduction

System Principle Block Diagram

Presents a block diagram illustrating the system architecture and component connections of the iM3 monitor.

Monitor Interface Description

Identifies and describes the various physical ports and connectors on the iM3 monitor.

Chapter 7 Troubleshooting

Machine Failures Troubleshooting

Lists common machine failures, their possible causes, and recommended solutions for the iM3 monitor.

Display Failures Troubleshooting

Details issues related to the monitor's display, including character display and screen blackouts, with troubleshooting steps.

Operation Failures Troubleshooting

Covers problems with user interface elements like buttons, touch screen, and rotary knob, providing solutions.

Recorder Failures Troubleshooting

Addresses issues with the printer, such as no paper output, blurred traces, or paper jams.

Network Failures Troubleshooting

Lists problems related to network connectivity, including inability to connect to Wi-Fi or wired networks.

Power Board Failures Troubleshooting

Explains troubleshooting steps for power-related issues, such as blown fuses.

Alarm Failures Troubleshooting

Describes issues with audio or visual alarms not activating and provides solutions.

Parameter Failures Troubleshooting

Covers problems with specific parameter measurements like NIBP and SpO2, including communication stops and inaccuracies.

Chapter 8 Disassembling the Monitor

Required Tools for Disassembly

Lists the necessary tools for disassembling and servicing the iM3 monitor.

Main Unit Disassembly Procedure

Provides a step-by-step guide to disassembling the main components of the iM3 monitor.

Front Housing Assembly Disassembly

Details the process of disassembling the front housing of the iM3 monitor to access internal components.

Rear Housing Assembly Disassembly

Guides the disassembly of the rear housing of the iM3 monitor.

Middle Frame Assembly Disassembly

Details the process of removing the middle frame assembly from the iM3 monitor.

Plug-in Module Disassembly

Outlines the disassembly of various plug-in modules for the iM3 monitor.

Chapter 9 Replaceable Parts

EDAN iM3 Specifications

General IconGeneral
SpO2Yes
NIBPYes
TemperatureYes
RespirationYes
Pulse RateYes
Display Size8.4 inches
BatteryRechargeable lithium-ion
Battery LifeUp to 4 hours
Storage Temperature-20 ~ 60 ℃