EasyManuals Logo

Edwards EXT70 User Manual

Edwards EXT70
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
© Edwards Limited 2013. All rights reserved. Page 57
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
B722-40-880 Issue F
The System Status Word returned is made up of 8 hexadecimal digits. To decode this word, convert each digit into a
4-digit binary number. (Table 25 is provided as an aid.) Follow the example below:
Each binary digit (bit) represents a flag that is either active (state 1) or not active (state 0). To help decode the
System Status Word, each bit is numbered (starting with 0 for the least significant to 31 for the most significant) as
shown below.
Table 26 contains a list of the lower 16 status flags that will be useful for fault finding. The upper 16 status flags are
reserved by Edwards.
Binary digits
Bit numbers
22830022
00100010100000110000000000100010
Table 25 - Hexadecimal conversion table
Hexadecimal Binary Decimal
000000
100011
200102
300113
401004
501015
601106
701117
810008
910019
A101010
B101111
C110012
D110113
E111014
F111115
00100010100000110000000000100010

3
1
3
0
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
9
1
8
1
7
1
6
1
5
1
4
1
3
1
2
1
1
1
0
9876543210
Table 26 - Status flags
Bit number Status flag Active flags means
0 Fail Fail status condition active
1 Stopped speed Below stopped speed
2 Normal speed Above normal speed