47
2
PV Input Mode
This setting allows the user to
set the PV Input Mode.
PV Input Type:
S=two independent strings,
P=same string input for 2
MPPTs
Default: S
3
Battery
This setting allows the user to identify if Batteries will be
used in the system and, if yes, the type of batteries (Lead-
Acid or Lithium).
Operate with No Battery
Step 1: Choose battery type first. When “no” begins
flashing, select Enter to operate with No Battery
Operate with Lead-Acid Battery
Step 1: Choose battery type first. When “Lead-Acid”
begins flashing, select Enter to operate with Lead-Acid
Batteries.
Step 2: Enter the Battery Capacity (Ah)
Operate with Lithium Battery
Step 1: Choose battery type first. When “Li-ion” begins
flashing, select Enter to operate with Lithium Batteries.
Step 2: Enter the Battery Brand
(e.g., 0=EG4, 2=Pylon, 6=LuxPower, 8=Dyness)
4
UPS Output
Voltage and
Frequency
This setting allows the user to
set the inverter output voltage
and frequency.
AC Output Voltage:
200VAC, 208VAC, 220VAC,
230VAC, 240VAC
Default: 240VAC
AC Output Frequency:
50Hz, 60Hz
Default: 60Hz
REMINDER: It is NOT recommended to operate without batteries