Eldan Recycling A/S Page 18
4.3.0 Setting: Max. Overload
The Max. Load MPR setting is used to stop the MPR inlet conveyor. If the load
is greater than the set value, the inlet conveyor will stop.
1. Press the Number to set the Max.
overload.
2. Enter the number as a percentage
(0-100%) and press Enter.
Adjustment
Max. Overload
0 %
4.2.1 Setting: Time delay
A time delay can be set so that the inlet conveyor does not stop if motor 1 or 2
is briefly overloaded.
Setting range: 1-3 seconds.
1. Press the Number to set the time
delay.
2. Enter the number as a percentage (1-
3 seconds) and press Enter.
Adjustment Time Delay
Max. Overload
0