Eldan Recycling A/S Page 40
14. TROUBLESHOOTING
No.
Colour/P
LC
input/
output
Function Possible fault
H1
Connection of main
switch
B351
White
I1.10
Control power supply
Check the power
supply.
Check the fuses.
Check whether the
main switch is switched
off (H1).
Turn the control current
key (B351) and press
Start/Reset.
B299
Green
I1.09
Reset. Reconnects
the control power
supply to the control
cabinet
Check whether an
emergency stop has
been activated or the
power supply has been
interrupted.
Touch panel fault messages
Fault messages
PLC
in/out
Function Possible faults
EMERGENCY
STOP ACTIVATED
I0.00 Emergency stop
Check that no
emergency stop has
been activated.
Press Start/Reset.
Control power
supply Off
I0.01 Control current key
Insert and turn the
control current key.
Service switch
B151
I0.03 Key switch
Blocking
MPR
I2007
Rotation
guard
Check the hopper for
material in MPR.
MAX.
TEMPERATURE
TR
I2008 Temperature sensor
Check whether the
temperature setting on
the Touch Panel is
correct.