Shipping and storage requirements
Systems and components must not experience changes in temperature and humidity
that are likely to cause condensation to form on or in that system or component. Do
not exceed the shipping and storage temperature gradient of 45°F/hr (25°C/hr).
Table 3 Shipping and storage requirements
Requirement Description
Ambient temperature -40° F to 149°F (-40°C to 65°C)
Temperature gradient 45°F/hr (25°C/hr)
Relative humidity 10% to 90% noncondensing
Elevation -50 to 35,000 ft (-16 to 10,600 m)
Dimensions and weight
Table 4
Shelf with no FRUs installed, dimensions and weight
Dimensions Vertical size Weight
Height: 8.75 in (22.23 cm) 5U
( 4U plus 1U cable
management tray)
Standard IEC-310 NEMA 19" 55.0 lb (20.4 kg)
Width, including rails: 17.50 in
(44.45 cm)
Depth: Chassis only: 34.5 in
(92.23 cm)
Greatest Feature Depth
36.35in (92.33 cm)
Table 5 Shelf with FRUs installed, dimensions and weight
Dimensions Vertical size Weight
Height: 8.75 in (22.23 cm) 5U
( 4U plus 1U cable
management tray)
Standard IEC-310 NEMA 19" 225.0 lb (90.7 kg)
Width: 17.50 in (44.45 cm)
Depth: 34.5 in (92.23cm)
Greatest Feature Depth
36.35in (92.33 cm)
Technical Specifications
Shipping and storage requirements 19