# enclosure show powersupply 11
This command may take up to a minute to complete. Please wait...
Enclosure Description Status
--------- --------------------- ------
4 Power module A pack 1 OK
4 Power module A pack 2 OK
4 Power module A pack 3 OK
4 Power module A pack 4 OK
4 Power module B pack 1 OK
4 Power module B pack 2 OK
4 Power module B pack 3 OK
4 Power module B pack 4 OK
--------- --------------------- ------
Complete the procedure
Procedure
1. Return the failed or replaced part(s) to EMC Data Domain. Reuse the packaging
from the new part(s) and use the included prepaid waybill for shipping.
Reference the RMA number on the outside of the package.
2. Send an autosupport report from the system by entering the autosupport
send command.
LCC replacement
This procedure describes how to remove and replace an LCC.
Identify the failed
Procedure
1. Check the rear of the shelf for the service LED of the affected .
If the needs to be replaced, the service LED is a solid amber.
2. Log in as sysadmin.
3. Enter the alerts show current command to display messages indicating
failure. A sample output is shown.
# alerts show current
Id Post Time Severity Class Object Message
---- ---------------------- -------- ------- --------- -----------------
p0-94 Mon Jun 1 9:46:27 2015 WARNING HWFailure Enclosure=9 EVT-MPATH-00006:
Path redundancy is lost.
Enclosure 9 only has
1 active connection path
and the required number is
2.
4. Enter the enclosure show controllers command to find the failed
controller 9:
# enclosure show controllers 9
Encl 9
Model
Capacity 60 Slots
WWN N/A
Serial # APM00151918344
Number of Controllers 1
Removing and Replacing FRUs
Complete the procedure 83