104 EZMotion User/Programming Guide
www.controltechniques.com Revision: A8
example of this.
Figure 108: Cumulative ON Timer with Reset - Timing Diagram
Cumulative OFF Timer
This type of timer works exactly like the Level OFF Timer, except that when the With this type of timer, when the Input of the timer
activates, the output turns ON. When the Input turns off, the internal clock begins to count. Once the Preset time is reached, the
Output of the timer turns OFF. If the Input turns ON again before the Preset time is reached, the clock resets to zero and waits again
for the Input to turn OFF before resuming the count again.
Figure 109: Cumulative Off Timer - Timing Diagram
Additionally, a Reset signal can be used to clear the cumulative timer and restart it at zero. The figure below shows an example of