Revision A8 www.controltechniques.com
is being processed.
For more information on the Where Am I, refer to Section 3 of this manual (Menu Bar or Toolbar descriptions).
14.3.5 Online View Tabs
Many of the Views in PowerTools Pro have feedback information displayed on an Online Tab. The Online Tab is only visible
when PowerTools Pro is communicating with the SM-EZMotion module.
The main Status Online Tab is found on the Status View, and it displays feedback and diagnostic parameters for the over all
system. Figure 186 is an example of the Status View - Online Tab.
Figure 186: Status View-Online Tab
Many of the views in PowerTools Pro have Online tab that contain parameters related to that view when online with the drive.
14.4 Clearing SLX.dF trip after installing SM-EZMotion module
After installing a SM-EZMotion module for the first time, the Unidrive SP will display a SLX.dF trip (where X is the slot number
that the SM-EZMotion module is in). This trip occurs because the drive detects the module type in the slot has changed. This
trip will occur on each successive power up until the drive parameter database has been saved. To save the drive parameter
database, follow the instructions below.
Saving the Drive Parameters
When changing a parameter in Menu 0, the new value is saved automatically when pressing the Mode button to
return to parameter view mode from parameter edit mode.
If parameters have been changed in the advanced menus, then the change will not be saved automatically. A save function
must be carried out.
The procedure for saving the parameters is as follows:
1. Enter the value 1000 in MM.00, where MM is any menu number.
2. Press the red Reset button.
14.5 Clearing the SM-EZMotion module memory
The SM-EZMotion module has a function that allows the user to clear the module memory. Doing so will erase the
configuration stored in the module. To procedure for erasing the module configuration is as follows:
1. Navigate to parameter 18.01 on the keypad
2. Press the Mode button to enter parameter edit mode
3. Enter the value 19237
4. Press the Mode button again to return to parameter view mode
5. Remove AC power from the Unidrive SP
M