198 EZMotion User/Programming Guide
www.controltechniques.com Revision: A8
Stop
Gear.Stop
Gear.Stop will stop gearing motion that has been initiated from a program using Gear.Initate.
Use Scale Check Box
Gear.UseScaleEnable
Select this check box to enable the scaling and disable the gear ratio. Scaling allows the user to use irrational ratios such as 1.0/7.0
that which is not possible with the single parameter, Gear.Ratio.
Graph.TriggerState
TriggerState
This parameter is used to control the Graph function from within a program.
0 = Filling Buffer: The whole buffer must be filled with selected data before trigger sampling starts
1 = Filled - Waiting Trigger: Continue putting data into the buffer, check back into previous sampled data for the trigger condition
2 = Manually Triggered: User pressed the stop button, the buffer will have what ever data is available
3 = Filled and Triggered: Stop loading buffer, trigger is found and offset data after the trigger is in the buffer ready for upload
Graph.TriggerState2
Graph State
This parameter is read-only and can be used in a program to show the state the graph is in.
0 = Filling Buffer: The whole buffer must be filled with selected data before trigger sampling starts
1 = Filled - Waiting Trigger: Continue putting data into the buffer, check back into previous sampled data for the trigger condition
2 = Manually Triggered: User pressed the stop button, the buffer will have what ever data is available
3 = Filled and Triggered: Stop loading buffer, trigger is found and offset data after the trigger is in the buffer ready for upload
Graph Run
GraphRun
This instruction allows the user to enable the graph from a user program. It is similar to pressing the Run button on the Graph view.
This instruction will wait until the graph buffer is full, then it exits into the looking for trigger state.
SlotX Module Type
Hardware.SlotXModuleType
This parameter defines the type of module fitted in the specified slot number. This parameter can be found on each of the SlotX
views. This parameter is read-only in a user program.
If the module type specified in the PowerTools Pro configuration does not match the actual module type fitted, EZMotion will
generate an error, and the drive will trip.
Home Any Command Complete
Home.AnyCommandComplete
This source is active when any home motion command is completed, if a stop is activated before the home has completed the
function will not be activated. Inactivated when a home command is executed.
Home Acceleration
Home.#.Accel
This parameter sets the average Acceleration rate used during the home, units are specified on the User Units page.
Home Accelerating
Home.#.Accelerating
Active during any acceleration while the specified home is in progress. Accelerating may turn off and on again based on the type of
Home selected. Accelerating will activate during the Home back off sensor motion.
Home At Velocity
Home.#.AtVel
This source is activated when the home velocity is reached when a the specified home is in progress. It will activate and deactivate
base on the home. Home At Velocity will not be activated during back off sensor portion of the home.