Table A-27: Rosemount 5303 Level for Solids Ordering Information (continued)
Transient protection
T1 Transient Protection Terminal Block. Selectable with HART 4-20 mA output (output code H).
Already included in all FOUNDATION Fieldbus variations.
★
Diagnostic functionality
D01 FOUNDATION Fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics) ★
DA1 HART Diagnostics Suite (includes Signal Quality Metrics diagnostics) ★
Overfill prevention
U1
(16)
WHG Overfill Approval ★
Extended product warranty
WR3
(17)
3-year limited warranty ★
WR5
(17)
5-year limited warranty ★
Remote housing mounting (see Figure A-37)
B1 1m / 3.2 ft. Remote Housing Mounting Cable and 316L Bracket
B2 2m / 6.5 ft. Remote Housing Mounting Cable and 316L Bracket
B3 3m / 9.8 ft. Remote Housing Mounting Cable and 316L Bracket
Engineered solutions (see Engineered solutions)
Rxxxx Engineered Solutions beyond standard model codes. (Consult factory for details)
Example model string: 5303-H-A-1-S-1-V-6A-M-025-50-AA-I1-M1C1.
E-025-05, means 25 ft. and 5 in. probe length. M-025-50, means 25.5 m.
(1) Not available with explosion-proof, flameproof, or type n approvals.
(2) Process seal rating. Final rating depends on flange and O-ring selection. See “Temperature and pressure limits” on
Process temperature and pressure rating, Flange rating, Tri-Clamp rating, and Plate design.
(3) For other materials, consult the factory.
(4) 0.79 lb (0.36 kg) standard weight for flexible single lead probe. L=5.5 in. (140 mm).
(5) Extra length for fastening is added in the factory.
(6) 1.2 lb (0.56 kg) standard weight for flexible single lead probe. L=5.5 in. (140 mm).
(7) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending
on selected probe length unit. If tank height is unknown, please round up to an even length when ordering. Probes can
be cut to exact length in field. Maximum allowable length is determined by process conditions. See Total probe length
for more probe length guidance.
(8) Available in 316L. For other materials, consult the factory.
(9) Available in 316L and EN 1.4404. For other materials consult the factory.
(10) Requires FOUNDATION Fieldbus signal output (U
i
parameter listed in Product certifications).
(11) G ½ in. SST cable gland is included in delivery.
(12) Available for tank connection with flange.
(13) The standard alarm setting is high.
(14) Weldings in accordance with EN/ISO standards.
(15) Certificate includes all pressure retaining wetted parts.
(16) Cannot be combined with E2 (INMETRO Flameproof) or I2 (INMETRO Intrinsic Safety).
(17) Rosemount extended warranties have a limited warranty of three or five years from date of shipment.
Specifications and reference data Reference Manual
April 2019 00809-0100-4530
342 Rosemount 5300 Level Transmitter