Table A-28: Rosemount 5300 Series Spare Parts List - Transmitter Head (continued)
Overfill prevention
U1
(11)
WHG Overfill Approval
Extended product warranty
WR3
(12)
3-year limited warranty
WR5
(12)
5-year limited warranty
Remote housing mounting
B1 1 m/3.2 ft. Remote Housing Mounting Cable and 316L Bracket
B2 2 m/6.5 ft. Remote Housing Mounting Cable and 316L Bracket
B3 3 m/9.8 ft. Remote Housing Mounting Cable and 316L Bracket
Engineered solutions
Rxxxx Engineered Solutions beyond standard model codes. (Consult factory for details)
(1) Not available with explosion-proof, flameproof, or type n approvals.
(2) Probes are intrinsically safe.
(3) G ½ in. SST cable gland is included in delivery.
(4) Requires FOUNDATION Fieldbus signal output.
(5) The standard alarm setting is high.
(6) Consider any temperature limitations dependent on Hazardous locations certifications.
(7) Option code BR5 together with option code QS or QT is pending, consult factory.
(8) Option code BR5 together with Remote housing options (B1, B2, B3) is pending, consult factory.
(9) Not available with option code U1.
(10) For ambient temperatures between -67 °F (-55 °C) and -40 °F (-40 °C), the ambient temperature effect is ± 0.012 in. (0.3
mm) /°K or ± 45 ppm/°K of measured value, whichever is greatest. Other performance specifications apply to ambient
temperatures between –40 °F (–40 °C) and 185 °F (85 °C).
(11) Cannot be combined with E2 (INMETRO Flameproof) or I2 (INMETRO Intrinsic Safety).
(12) Rosemount extended warranties have a limited warranty of three or five years from date of shipment.
Table A-29: Rosemount 5300 Series Spare Parts List - Probe
Model Product description
5309 Spare probe
Signal output
N Not Applicable
Housing material
N Not Applicable
Conduit / cable threads
0 Not Applicable
Operating temperature and pressure (see Process temperature and pressure
rating)
(1)
Probe Type
S Standard:
- 15 to 580 psig @ 302 °F
(-1 to 40 bar @ 150 °C)
1A, 2A, 3A, 3B, 3C, 4A, 4B,
4S, 5A, 5B, 6A, and 6B
Specifications and reference data Reference Manual
April 2019 00809-0100-4530
346 Rosemount 5300 Level Transmitter