Unidrive M702 User Guide            221
Issue Number: 3          
4.10.054 Rx2 Source Type
Direct (0), Multicast1 (1), Multicast2 (2), 
Multicast3 (3), Multicast4 (4), Local (5) 
Direct (0) RW Txt
US
4.10.055 Rx2 Timeout 0 to 65535 ms 100 ms RW Num
US
4.10.056 Rx2 Timeout Action Trip (0), Clear output (1), Hold last (2) Trip (0) RW Txt
US
4.10.057 Rx2 Timeout Event Destination
This slot (0), Slot 1 (1), Slot 2 (2), 
Slot 3 (3), Slot 4 (4)
This slot (0) RW Txt
US
4.10.058 Rx2 Timeout Event Type
No event (0), Event (1), Event1 (2), 
Event2 (3), Event3 (4)
No event (0) RW Txt
US
4.10.059 Rx2 Link Status
Invalid profile (-16), Invalid mapping (-15), Read only 
param (-14), Timeout (-8), 
In error (-7), Link num in use (-6), 
Not editable (-5), Invalid link num (-4), Invalid args (-3), 
Too many links (-2), Out of memory (-1), OK (0)
OK (0) RO Txt
4.10.060 Rx3 Link Profile 0 to 0 0 RW Num
US
4.10.061 Rx3 Link Number 0 to 255  0 RW Num
US
4.10.062 Rx3 Destination Parameter 0.00.000 to 4.99.999  0.00.000 RW Num DE
US
4.10.063 Rx3 Parameter Count 0 to 32 0.000 RW Num
US
4.10.064 Rx3 Source Type
Direct (0), Multicast1 (1), Multicast2 (2), 
Multicast3 (3), Multicast4 (4), Local (5) 
Direct (0) RW Txt
US
4.10.065 Rx3 Timeout 0 to 65535 ms 100 ms RW Num
US
4.10.066 Rx3 Timeout Action Trip (0), Clear output (1), Hold last (2) Trip (0) RW Txt
US
4.10.067 Rx3 Timeout Event Destination
This slot (0), Slot 1 (1), Slot 2 (2), 
Slot 3 (3), Slot 4 (4)
This slot (0) RW Txt
US
4.10.068 Rx3 Timeout Event Type
No event (0), Event (1), Event1 (2), 
Event2 (3), Event3 (4)
No event (0) RW Txt
US
4.10.069 Rx3 Link Status
Invalid profile (-16), Invalid mapping (-15), Read only 
param (-14), Timeout (-8), 
In error (-7), Link num in use (-6), 
Not editable (-5), Invalid link num (-4), Invalid args (-3), 
Too many links (-2), Out of memory (-1), OK (0)
OK (0) RO Txt
Parameter
Range Default
Type
OL RFC-A RFC-S OL RFC-A RFC-S
RW Read / Write RO Read only Num Number parameter  Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination