178 Unidrive M702 User Guide
Issue Number: 3
11.7 Menu 7: Temperature monitoring
Parameter
Range(
)Default()
Type
OL RFC-A / S OL RFC-A RFC-S
07.004 Monitored Temperature 1 ±250 °C RO Num ND NC PT
07.005 Monitored Temperature 2 ±250 °C RO Num ND NC PT
07.006 Monitored Temperature 3 ±250 °C RO Num ND NC PT
07.033 Power Output ±100.0 % RO Num ND NC PT
07.034 Inverter Temperature ±250 °C RO Num ND NC PT
07.035 Percentage Of d.c. Link Thermal Trip Level 0 to 100 % RO Num ND NC PT
07.036 Percentage Of Drive Thermal Trip Level 0 to 100 % RO Num ND NC PT
07.037 Temperature Nearest To Trip Level 0 to 29999 RO Num ND NC PT
07.038 Temperature Monitor Select 1 0 to 29999 1001 RW Num US
07.039 Temperature Monitor Select 2 0 to 29999 1002 RW Num US
07.052 Temperature Monitor Select 3 0 to 29999 1 RW Num US
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination