EasyManua.ls Logo

Emerson Unidrive M702 - Page 177

Emerson Unidrive M702
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization
NV Media Card
Operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
Unidrive M702 User Guide 177
Issue Number: 3
06.057 Sleep Active Off (0) or On (1) RO Bit ND NC PT
06.059 Output Phase Loss Detection Enable Off (0) or On (1) Off (0) RW Bit US
06.060 Standby Mode Enable Off (0) or On (1) Off (0) RW Bit US
06.061 Standby Mode Mask 0000000 to 1111111 0000000 RW Bin US
06.065 Standard Under Voltage Threshold ±VM_STD_UNDER_VOLTS V
200 V drive: 175 V
400 V drive: 330 V
575 V drive: 435 V
690 V drive: 435 V
RW Num RA US
06.066 Low Voltage Under Voltage Threshold ±VM_LOW_UNDER_VOLTS V
200 V drive: 175 V
400 V drive: 330 V
575 V drive: 435 V
690 V drive: 435 V
RW Num RA US
06.067 Low Under Voltage Threshold Select Off (0) or On (1) Off (0) RW Bit US
06.068 Back Up Supply Mode Enable Off (0) or On (1) Off (0) RW Bit US
06.069 Under-Voltage System Contactor Close Off (0) or On (1) RO Bit ND NC PT
06.070 Under-Voltage System Contactor Closed Off (0) or On (1) Off (0) RW Bit US
06.071 Slow Rectifier Charge Rate Enable Off (0) or On (1) Off (0) RW Bit US
06.072 User Supply Select Off (0) or On (1) Off (0) RW Bit US
06.073 Braking IGBT Lower Threshold ±VM_DC_VOLTAGE_SET V
200 V drive: 390 V
400 V drive: 780 V
575 V drive: 930 V
690 V drive: 1120 V
RW Num US
06.074 Braking IGBT Upper Threshold ±VM_DC_VOLTAGE_SET V
200 V drive: 390 V
400 V drive: 780 V
575 V drive: 930 V
690 V drive: 1120 V
RW Num US
06.075 Low Voltage Braking IGBT Threshold ±VM_DC_VOLTAGE_SET V 0 V RW Num US
06.076
Low Voltage Braking IGBT
Threshold Select
Off (0) or On (1) Off (0) RW Bit
Parameter
Range(
) Default()
Type
OL RFC-A / S OL RFC-A RFC-S
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination

Table of Contents

Other manuals for Emerson Unidrive M702

Related product manuals