Figure 11-23 Menu 9 logic diagram: Scope function
09.062
x(-1)
Scope
Trigger Invert
09.059
09.061
09.060
OR
+
_
Scope
Trigger
Scope Trigger
Source
Scope Trigger
Threshold
09.063 Scope Mode
09.067 Scope Sample Time
09.068
Scope Trigger Delay
09.069 Time Period
09.055
09.057
09.056
09.064
09.058
09.065
Scope Data
Not Ready
09.066
Scope Saving
Data
Scope Trace 1
Source
Scope Trace 2
Source
Scope Trace 3
Source
Scope Trace 4
Source
Scope Arm
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings