11.12 Menu 12: Threshold detectors, variable selectors and brake control function
Figure 11-24 Menu 12 logic diagram
??.???
Any variable
parameter
??.???
12.003
Threshold
Detector 1
Source
12.004
Threshold
Detector 1
Threshold
Detector 1
x(-1)
12.006
Threshold
Detector 1
Output Invert
12.001
12.005
Threshold
Detector 1
Hysteresis
??.???
Any
unprotected
bit parameter
??.???
12.007
Threshold
Detector
Destination
Parameter
1
??.???
Any variable
parameter
??.???
12.023
Threshold
Detector 2
Source
12.024
Threshold
Detector 2
Level
Threshold
Detector 2
Threshold
Detector 2
x(-1)
12.026
Threshold
Detector 2
Output
Invert
12.002
Threshold
Detector 2
Output
12.025
Threshold
Detector 2
Hysteresis
??.???
??.???
12.027
Threshold
Detector
Destination
2
All parameters are shown
at their default setting
Hysteresis
Threshold
level
Threshold
output
t
t
Any
unprotected
bit parameter
Threshold
Detector 1
Level
Threshold
Detector 1
Output
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings