Table 12-5 Losses @ 40°C (104°F) ambient with high IP insert installed
Model
Normal Duty
Heavy Duty
Drive losses (W) taking into consideration any 
current derating for the given conditions
Drive losses (W) taking into consideration any 
current derating for the given conditions
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
200 V
03200050
03200066
03200080
03200106
04200137
04200185
05200250
400 V
03400025
03400031
03400045
03400062
03400078
03400100
04400150
04400172
05400270
05400300
575 V
05500030
05500040
05500069