Safety 
information
Product 
information
Mechanical 
installation
Electrical 
installation
Getting 
started
Basic 
parameters
Running 
the motor
Optimization
NV Media Card 
Operation
Onboard 
PLC
Advanced 
parameters
Technical 
data
Diagnostics
UL listing 
information
Unidrive M702 User Guide             97
Issue Number: 3          
00.042 Number Of Motor Poles {05.011} Automatic (0) to 480 Poles (240) Automatic (0) 6 Poles (3)
RW Num US
00.043
Rated Power Factor {05.010} 0.000 to 1.000 0.850
RW Num RA US
Position Feedback Phase Angle {03.025}
0.0 to 
359.9 °
RW Num ND US
00.044 Rated Voltage {05.009} ±VM_AC_VOLTAGE_SET
200V drive: 230V
50Hz default 400V drive: 400V
60Hz default 400V drive: 460V
575V drive: 575V
690V drive: 690V
RW Num RA US
00.045
Rated Speed {05.008}
0 to 
180000 rpm
0.00 to 
50000.00 
rpm
50Hz default: 
1500 rpm
60Hz default: 
1800rpm
50Hz default: 
1450 rpm
60Hz default: 
1750rpm
RW Num US
Motor Thermal Time Constant 1 {04.015}
1.0 to 
3000.0 s
89.0 s
RW Num US
00.046 Rated Current {05.007} ±VM_RATED_CURRENT Maximum Heavy Duty Rating (11.032)
RW Num RA US
00.047 Rated Frequency {05.006}
0.0 to 
3000.0 Hz
0.0 to 
1667.0 Hz
50Hz default: 50.0 Hz
60Hz default: 60.0 Hz
RW Num US
00.048 Drive Mode {11.031} Open-loop (1), RFC-A (2), RFC-S (3), Regen (4) Open-loop (1) RFC-A (2) RFC-S (3)
RW Txt ND NC PT
00.049 User Security Status {11.044}
Menu 0 (0), All Menus (1), Read-only Menu 0 (2), 
Read-only (3), Status Only (4), No Access (5)
Menu 0 (0)
RW Txt ND PT
00.050 Software Version {11.029} 0 to 99999999
RO Num ND NC PT
00.051 Action On Trip Detection {10.037} 0 to 31 0
RW Bin US
Parameter
Range Default
Type
OL RFC-A RFC-S OL RFC-A RFC-S
RW Read / Write RO Read only Num Number parameter  Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination
IP IP address Mac Mac address Date Date parameter Time Time parameter