Cerabar S/Deltabar S Description of parameters (FF configuration program)
Endress+Hauser 57
NUMBER_OF_SENSOR_
CHANGES/
SENSOR CHANGES
Display
Index: 40
Data type: Float
Access: Read only
Displays the number of sensor changes that have already been carried out.
PEAK_HOLD_
INCREMENT_FACTOR/
P. PEAKHOLD STEP
Display
Index: 41
Data type: Float
Access: Read only
Displays the key distance at which the pressure peak indicator values are saved. The value is
displayed as a factor of the sensor end value. The pressure peak indicator values are saved
every 15 minutes regardless of this value.
TEMPERATURE_1_
PEAK_HOLD_
INCREMENT_OFFSET/
T. PEAKHOLD STEP
Display
Index: 42
Data type: Float
Access: Read only
Displays the key distance at which the temperature peak indicator values are saved. The
value is displayed in Kelvin. The temperature peak indicator values are saved every 15
minutes regardless of this value.
ACCELERATION_OF_
GRAVITY/
ACC. OF GRAVITY
Display
Index: 43
Data type: Float
Access: Read only
Displays the gravitational acceleration used by the device for calculating the measured
variables in the "Level" measuring mode.
CREEP_FLOW_
SUPPRESSION_
HYSTERESIS/
CREEP FLOW HYST
Display
Index: 44
Data type: Float
Access: Read only
Displays the hysteresis for low flow cut off. → See also Page 49, Pressure Transducer Block,
parameter description for LOW_FLOW_CUT_OFF/SET. L. FL. CUT-OFF.
Factory setting:
1 % (of end flow value)
HISTOROM_SAVING_
CYCLE_TIME/
HIST. SAVING CYCL.
Display
Index: 45
Data type: Unsigned8
Access: Read only
Displays the interval at which the measured value is saved.
HISTOROM_
AVAILABLE/
HistoROM AVAIL.
Display
Index: 46
Data type: Unsigned8
Access: Read only
Indicates whether the optional HistoROM®/M-DAT memory module is connected to the
electronic insert.
→ See also Operating Instructions BA301P (Deltabar S) or BA302P (Cerabar S), Section 5.4
"HistoROM
®
/M-DAT (optional)".
Options:
•Yes (HistoROM
®
/M-DAT is attached to the electronic insert)
• No (HistoROM
®
/M-DAT is not attached to the electronic insert)
Service Transducer Block
Parameter Description