Diagnostics and troubleshooting Proline Promass E TB2 HART
86 Endress+Hauser
Diagnostics event Event text Remedial measures
Event level from the
factory
S044 Sensor drift Electrodynamic sensor signal deviation!
1. Check or change main electronics.
2. Change sensor.
Warning
1)
S046 Sensor limit The measuring tube oscillation frequency is
outside the permitted range!
1. Inspect sensor.
2. Check process condition.
Warning
1)
F062 Sensor connection 1. Change main electronic module.
2. Change sensor.
Alarm
F082 Data storage 1. Change main electronic module.
2. Change sensor.
Alarm
F083 Memory content 1. Restart device.
2. Restore S-Dat data.
3. Change sensor.
Alarm
1) Event level can be changed: Chapter 12.5.1 "Adapting event level"
12.5.3 Diagnostics for the electronics
Diagnostics event
Event text Remedial measures
Event level from the
factory
F242 Software incompatible 1. Check software.
2. Flash or change main electronics module.
Alarm
F252 Modules incompatible 1. Check electronic modules.
2. Change I/O or main electronics module.
Alarm
1)
F261 Electr. modules 1. Restart device.
2. Check electronic modules.
3. Change I/O Modul or main electronics.
Alarm
F262 Module connect. 1. Check module connections.
2. Change electronics modules or sensor.
Alarm
F270 Main electronic Change main electronics module. Alarm
F271 Main electronic 1. Restart device.
2. Change main electronic module.
Alarm
F272 Main electronic 1. Restart device.
2. Contact service.
Alarm
F273 Main electronics Emergency operation via display!
Change main electronics.
Alarm
S274 Main electronic Unstable measurement!
Change the main electronics.
Warning
1)
F275 I/O module Change I/O module. Alarm
F276 I/O module 1. Restart device.
2. Change I/O module.
Alarm
F282 Data storage 1. Restart device.
2. Contact service.
Alarm
F283 Memory content 1. Transfer data or reset device.
2. Contact service.
Alarm
F311 Electronics error 1. Transfer data or reset device.
2. Contact service.
Alarm
M311 Electronics error Maintenance required!
1. Do not perform reset.
2. Contact service.
Warning
1) Event level can be changed: Chapter 12.5.1 "Adapting event level"