Enertech Global
EAV - EME/EMD Rev. A Models
Installaon and Operaons Manual
Under sengs, scroll down to Domesc Hot Water (aer
entering passcode).
• Electric immersion heat is used
under high demand situaons. Immersion heat is engaged
aer adjustable Aux HW Delay seng.
• Compressor only hot water, no
electric immersion heat is used (not recommended).
3.1.1 Before Code 3.1.2 Before Code 3.1.0 Advanced Passcode
3.2.0 3.2.1 Heat Curve 3.3.0
3.4.1 Heat Min Temp 3.4.2 Heat Max Temp 3.4.3 Cool Setpoint
3.1.1 After Code (note: le name is 3.1.0.BMP) 3.1.1 Aux Heat Delay
3.3.1 Heat Setpoint 3.4.0
3.5.0 3.5.1 Aux HW Delay
3.6.0 3.6.1 Hot Water Setpoint 3.6.2 Hot Water Deadband
3.7.2 Load Pump Max Speed 3.7.3 Delta Temp Heat Setpoint 3.7.4 Deta Temp Cool Setpoint
3.8.1 Pressure Units 3.8.2 Replace Filter 3.9.0
3.7.0 3.7.1 Load Pump Min Speed
3.7.5 Temp Units 3.8.0
3.9.0.1 3.9.0.2
• See Indoor Climate.
• Target tank temperature for DHW
operaon.
• Temperature dierence from
setpoint to minimum temperature the tank can drop to
before heat pump is engaged.