EB-E01 series Appendix INTERNAL USE ONLY
SEIKO EPSON 176 Revision A
AS MENU: 5TH PAGE
Warning histories are displayed. The last 4 error logs are displayed (the latest
on top). You can switch the pages by up/down button of the remote controller.
None is displayed if there is no error.
No. Item
1 Warning item
2 Warning log (The latest warning log is displayed on the top.)
**ErrorInfo[1/1]
D:2016072211:22:33T:13h1m1sL:13hP:10h3m1s
[ERR]FanLV2(WarmUp)angle:Front
D:2016072211:22:33T:13h1m1sL:13hP:10h3m1s
[WAR]EasyMPInternal(Normal)PwrOnCont:20
angle:X=0016Y=1125Z=1AFF
D:2016072211:22:33T:13h1m1sL:13hP:10h3m1s
[ERR]I2CSil9679
D:2016072211:22:33T:13h1m1sL:13hP:10h3m1s
[ERR]ROMdrvSML.cpp321
Error Log
D: Date Time T: Lamp Time 1 L: Lamp Time 2 P: Lamp Time 3
[ERR] Error name (Error code), Device ID, Angle
Error Detail Information
Date yyyy_mm_dd
Time hh_mm_ss
Lamp Time 1 Total Time
Lamp Time 2 Low Brightness Time
Lamp Time 3 Elapsed Time
Error name Error Name P.179
Error Name Error Name P.179
Device ID
*Grey cell is Non-applied ID for this model. P.179
Device ID name (sensor error) P.180
Device ID name (internal error) P.182
Error Detail
Information
IC2 error: Add slave/sub address
ROM error: Add Inspection of Troubling Location
Lens shift error: Add Lens shift position
Angle x=0000 y=0000 z=0000
Warning Log
D: Date Time T: Lamp Time 1 L: Lamp Time 2 P: Lamp Time 3
[WAR] Warning Name (Warning Code)
Date yyyy_mm_dd
Time hh_mm_ss
Lamp Time 1 Total Time
Lamp Time 2 Low Brightness Time
Lamp Time 3 Elapsed Time
Error name Warning name P.179
Error Name Warning name P.179