EPSON Stylus Color 980 Revision A
Product Description Interface 20
NOTE:tt-out shows the rise and fall time of every output signal.
tt-in shows the rise and fall time of every input signal.
Typical time of tack is shown in Table 1-11.
Table 1-11. Typical Time of Tack
Table 1-12. Signal level for TTL Compatible
(IEEE-1284 level 1 device)
* A LOW logic level on the Logic H signal is as follows:
2.0 V or less when the printer is turned off.
3.0 V or more when the printer is turned on.
The receiver provides an impedance equivalent to 7.5 K
to
ground.
See Table 1-13 which shows the connector pin assignment and signals
for the forward channel of the parallel interface.
Table 1-10. Data Transmission Timing
Parameter Minimum Maximum
tsetup 500ns ---
thold 500ns ---
tstb 500ns ---
tready 0 ---
tbusy --- 500ns
tt-out* --- 120ns
tt-in** --- 200ns
treply 0 ---
tack 500ns 10us
tnbusy 0 ---
tnext 0 ---
Parallel Interface Mode Typical Time of Tack
High speed 1 us
Normal speed 3 us
Parameters Minimum Maximum Condition
VOH* --- 5.5V
VOL* -0.5V ---
IOH* --- 0.32mA VOH = 2.4V
IOL --- 12mA VOL = 0.4V
CO --- 50pF
VIH --- 2.0V
VIL 0.8V ---
IIH --- 0.32mA VIH = 2.0V
IIL --- 12mA VIL = 0.8V
CI --- 50pF

Table of Contents

Other manuals for Epson Stylus Color 980

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson Stylus Color 980 and is the answer not in the manual?

Epson Stylus Color 980 Specifications

General IconGeneral
BrandEpson
ModelStylus Color 980
CategoryPrinter
LanguageEnglish

Related product manuals