Stylus Pro 4880 Field Repair Guide 1/17/08
Multi Sensor Adjustment Printer Component, Software Item, LCD Display, Printer Button  Page 151.
Multi Sensor Adjustment
Note: The Multi Sensor Adjustment for Auto Nozzle Check calibrates the Auto Nozzle Check function.
1. Load 17” Enhanced Matte roll paper.
2. From the Adjustment Wizard for the Pro 4880, select the Mulit Sensor Adjustment for Auto 
Nozzle Check.
4. Click the Finish button.
3. The Printer will read the alignment pat-
tern automatically (using the Multi Sen-
sor), and write the appropriate values to 
the board.
1. Click on the Select Sensor Adjustment-
button.
2. Click on the Run button.