Stylus Pro 4880 Field Repair Guide 1/17/08
Pump and Cap Installation Printer Component, Software Item, LCD Display, Printer Button  Page 89.
Pump and Cap Installation
1. Before installing the Pump and Cap Assembly identify the Tube Receptacles where the Pump 
Tubes must be inserted.
2. Before installing the Pump and Cap Assembly, note this detail.
Tubes go here
Blow up view
The Plastic Tray that sits under 
the Pump, and that the Tubes 
are inserted into, has one corner 
that sits on top of the Pump / 
Cap Assembly Frame.
View from the bottom. Note the 
Plastic Tray is on top of the 
Frame Mount.
View from the back of the Printer. 
The Plastic is on top of the 
Frame.