EasyManua.ls Logo

Epson TM-U675 - Page 177

Epson TM-U675
325 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev.D Adjusting and Setting 3-9
TM-U675/U675P (with autocutter) Service Manual
Confidential
5. Using the thickness gauges, adjust the platen stopper screws so that the positions indicated
below are 0.5
±
0.05 mm.
The stopper screws for the platen set are located here.
Figure 3-9
Note:
Adjust the platen gap to meet the following conditions (0.5
±
0.05 mm).
The 0.45 mm thickness gauge falls under its own weight.
The 0.50 mm thickness gauge is pinched and will not fall between the platen and the print
head unit.
6. Attach the ribbon cassette cover and the carriage cover set frame.
20 mm 40 mm
0.5 +/- 0.05 mm
Adjustment Screw
Gauge
Print Head
Adjustment Screw

Table of Contents

Other manuals for Epson TM-U675

Related product manuals