VT6L Maintenance 11. Joint #3
VT series Maintenance Manual Rev.2 91
(
11)
Turn
ON the Manipulator.
Reference: VT series Manual VT6L Manipulator 6.5 LED
When starting the
Manipulator for the first time after replacing the motor unit, the
motor unit firmware is
automatically updated. DO NOT turn OFF the Manipulator
until it starts.
When you connect a motor unit connected to another axis, an error 5009 or 9709 will
occur. To clear the error, enter the following command in [Command Window] and
execute it.
Joint #1: > MUIDReset 1
Joint #2: > MUIDReset 2
Joint #3: > MUIDReset 3
Joint #4: > MUIDReset 4
Joint #5: > MUIDReset 5
Joint #6: > MUIDReset 6
Reboot the Controller.
(1
2)
Calibrate the Joint #
3.
Reference: 19. Calibration
NOTE

Table of Contents