VT6L  Maintenance  10. Joint #2 
 
VT series Maintenance Manual    Rev.2  77 
 
Disconnect the following connectors of the motor.
 
A: Signal cable connectors (for motor × 2) 
B: Signal cable connector (for AMP board) 
 
The cables will be necessary again.
 
Be careful not to lose them.
 
 
Remove the AMP board fixing plate (with AMP board) from 
the 
motor unit. 
Hexagon socket head cap bolts: 2-M3×6