Fix the AMP board fixing plate (with AMP board) to a new 
motor unit.
 
Hexagon socket head cap bolts: 2-M3×6 
Tightening torque: 2.0 ± 0.1 N·m 
 
Connect the following connectors of the motor.
 
A: Signal cable connectors (for motor × 2) 
B: Signal cable connector (for AMP board) 
 
Connector for the signal cable connector (for motor) is the 
same color.
 
 
Connect the connectors of the AMP board.
 
A: Power cable connector 
B: Brake connector 
C Signal cable connector (for AMP board) 
D: Motor connector 
 
thermal conductive sheet on the bottom of the 
motor unit.    For the attaching position, refer to the picture 
on the right.
 
Make sure that the entire surface of the 
thermal conductive 
 contacts with the rear side of the motor unit without 