VT6L  Maintenance  10. Joint #2 
 
VT series Maintenance Manual    Rev.2  81 
 
Manipulator. 
Reference: VT series Manual VT6L Manipulator 6.5 LED 
When starting the Manipulator for the first time after replacing the motor unit, the motor 
unit firmware is automatically updated.    DO NOT turn OFF the Manipulator until it 
starts.
 
When you connect a motor unit connected to another axis, an error 5009 or 9709 will 
occur. To clear the error, enter the following command in [Command Window] and 
execute it. 
Joint #1: > MUIDReset 1 
Joint #2: > MUIDReset 2 
Joint #3: > MUIDReset 3 
Joint #4: > MUIDReset 4 
Joint #5: > MUIDReset 5 
Joint #6: > MUIDReset 6 
Reboot the Controller. 
 
 
Reference: 19. Calibration