10 Appendix | 136
10.3 Custom Operations
What MDA V7 Migrated formula in MDA V8 Comment
Average Average (signal) Accumulate_Prefix_Average
(signal)
Average since measure start.
AND BinaryAND (signal, mask) If a measure signal is used:
Raw(signal) & mask
If a value is used:
notsignal & mask
All measure signal arguments are wrapped by
the Raw function.
Time range: From start
OR BinaryOR (signal, mask) If a measure signal is used:
Raw(signal) | mask
If a value is used:
notsignal | mask
All measure signal arguments are wrapped by
the Raw function.
Time range: From start
XOR BinaryXOR (signal, mask) If a measure signal is used:
Raw(signal) ^ mask
If a value is used:
notsignal ^ mask
All measure signal arguments are wrapped by
the Raw function.
Time range: From start
Const Const (value) value The dialogue in MDA V7 restricts the raster
selection to the fixed time raster.
Time range: From start
MDA V8 | User Guide

Table of Contents

Related product manuals