NAV IP Access controller
49
5.6.4.15 Fire Alarm Setting
Underthebelowwindow,press toconfigurethefirealarmfeatureofanalarminput:
Firealarm settingis usedtoconfigureotheralarm inputsas thefire alarminput.Firealarminput does
notfollowthearmdelaytime,ithasthehighestpriority.Itistriggeredaslongasthealarminputdefined
asfirealarmisconfigured.All10alarminputscanbedefinedfirealarminput.
5.6.4.16 Alarm Action Setting
AlarmActionSettingisusedtoconfiguretheallocationbetweenthephysical alarminputandtheoutput
onmainmodule,doormoduleandalarmmodule.
Presstoconfigurealarmactionsettingwhenthefollowingwindowappears.
NAV Controller providestotal 18 alarm outputs: 2alarm outputs on main module, 8 alarmoutputs on
doormodule,8alarmoutputsonalarmmodule.Theyareallocatedin3submenus,shownasthebelow
windows:
The first menu is “Alarm Act Setting on Main Module”. Press to enter to
the setting, LCD screen
shows the current status of thealarm output. Y indicatesthe alarm output isenabled; N indicates the
alarmoutputisdisabled.
Themainmoduleprovidestwoalarmoutputs,presskey“1”and“2”totogglethealarmoutput1,2ON
andOFF
Press to
switchto“AlarmActSettingonDoorModule” submenu.Press toentertothesetting,
LCDscreenshowsthecurrentstatusofthealarmrelayoutputsonthedoormodule.
Upto4doormodulescanbeinstalledontheNAVController.2alarmoutputsareavailableoneachdoor
module.Asaresult,upto8alarmoutputscanbeavailableif4doormodulesareinstalled.Pressnumeric
key1~8totogglethealarmoutputondoormodulebetweenONandOFF.
Alarm act on door
NNNNNNNN
Alarm act on main
YN
Alarm Act Setting
on Extern Moudle
Alarm Act Setting
on Door Moudle
Alarm Act Setting
on Main Moudle
Alarm Action Setting
Fire Alarm
Other alarm input
Fire Alarm
Fire alarm input
Fire Alarm Setting