Design and function
Configuring the welding machine for mechanical arc fusion welding
54
099-000115-EW501
17.06.2015
5.11.4 Function sequences/operating modes
The welding current operating mode must be set to latched on the welding machine. The welding
current is infinitely adjustable by means of torch triggers 3 and 4 (BRT 3 and BRT 4). Torch
trigger 2 (BRT 2) switches the welding current on or off.
Torch trigger 1 (BRT 1) switches the wire feed on or off. The operator can choose between three
operating modes (see following function sequences).
Figure 5-15
5.11.4.1 Explanation of symbols
Symbol
Meaning
Press torch trigger
Release torch trigger
Tap torch trigger (press briefly and release)
Shielding gas flowing
I
Welding output
Gas pre-flows
Gas post-flows
Non-latched
Special, non-latched
Latched
Special, latched
t
Time
P
START
Ignition program
P
A
Main program
P
B
Reduced main program
P
END
End program
tS1
Slope duration from PSTART to PA
Wire feed