Communicating Through TCP/IP Over Telnet
FTB-2/FTB-2 Pro and FTB-4 Pro 485
Internal Commands of the TCP/IP over Telnet Protocol
KILL LINS
Description This command allows any user to terminate the
session that contains the specified connection (LINS),
if this connection has been previously established
with the CONNECT LINS command (see CONNECT
LINS on page 483). This means that it will terminate
all active connections that belong to a session if these
connections have been previously established with
CONNECT LINS.
Syntax The syntax of the command vary according to the
type of platform you are using.
For IQS-600 and FTB-500:
KILL LINS<Unit_Number><Slot_Number>
You must specify the unit number and the slot
number identifying the module for which you
want to terminate the session.
For LTB-1, LTB-8, FTB-2, FTB-2 Pro, and FTB-4 Pro:
KILL LINS<Logical_Instrument_Number>
You must specify the logical instrument number
corresponding to the module for which you want
to terminate the session. This number is
configurable from the Remote Control
Configuration application.
Examples
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for EXFO FTB-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EXFO FTB-2 and is the answer not in the manual?

EXFO FTB-2 Specifications

General IconGeneral
BrandEXFO
ModelFTB-2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals