5.3 OPERATING LOGICS
In all the logics:
- the STOP command has priority and stops the
automation from operating
- the EMR command has priority and opens the
automation
- if no devices are engaged, a CLOSE pulse causes
the automation to close
■ Automatic logics:
-
A - Automatic
-
A1 - Automatic 1
-
PA - Automatic Parking
-
CA - Automatic Condominium
■ Semi-automatic logics:
-
E Semi-automatic E
-
P - Car park
-
Cn - Condominium
■ Dead-man logic:
-
C - Dead-man
■ Logic CU - Custom
When a default logic is customized in expert program-
ming mode, a CU - custom logic is created.
AUTOMATIC LOGICS
In all automatic logics, the OPEN and LOOP1 com-
mands:
- with the beam closed, open and close the automa-
tion automatically after a pre-set pause time
- reverse to open during closing
■
A - Automatic
If the Photocell / LOOP2 is triggered:
- during the pause, it reloads the pause time
- during closing, it reverses to open and closes again
after the pause time
■
A1 - Automatic 1
If the Photocell / LOOP2 is triggered:
- during opening, when the movement has ended
and when released, it closes the automation
- during closing, it reverses to open. When the
movement has ended and when released, it closes
the automation
■
PA - Automatic Parking
If the Photocell / LOOP2 is triggered:
- during closing, it stops the movement. When
released, it continues to close
If LOOP2 is triggered:
- during opening, when the movement has ended
and when released, it closes the automation
■
CA - Automatic Condominium
If the Photocell is triggered:
- during closing, it reverses to open and closes again
after the pause time
If LOOP2 is triggered:
- during opening, when the movement has ended
and when released, it closes the automation
- during closing, it reverses to open. When the
movement has ended and when released, it closes
the automation.