B680H 64 732719 - Rev.E
Translation of the original instructions
ENGLISH
10.4 OPERATIONAL PROBLEMS
15 Troubleshooting
CONDITION
FINDING SOLUTIONS
The barrier does not perform the SETUP
The barrier does NOT OPEN
Make sure that the automation has not been released
Make sure there is power
Check the motor and encoder connection
The barrier CLOSES rather than OPENING and vice versa.
Invert the phases in the motor connection and carry out the setup
The barrier makes very slow movements
Check the force set
Make sure that the beam is balanced
Make sure that the parameter
cF has been set according to the length of
the beam
If the barrier working on the battery, make sure that the battery is charged.
The barrier moves irregularly
Check the motor connection and make sure that the encoder is working
correctly
The barrier does NOT OPEN
Make sure that the automation has not been released
Check the driving direction of the motor
The barrier does NOT CLOSE
Make sure that the automation has not been released
Check the driving direction of the motor
Check the LED status of the controls, loops, safety devices and EMR are not
active
The barrier does NOT OPEN and does NOT CLOSE
Make sure that the automation has not been released
Check the status of the STOP LED is not active
Check the motor and encoder connection
The barrier moves irregularly and is very noisy during the
opening and closing cycles
Make sure there is no air in the hydraulic circuit, bleed it if necessary.