5 Expert Programming
Expert Function Setting
01
Enabling this function causes automatic closing after the pause time.
Y = automatic closing
no = disabled
02
If you enable this function, operation is with two different inputs:
OPEN for opening and CLOSE for closing.
Y = operation with 2 inputs
no = disabled
03
Level recognition activation for the OPEN and CLOSE inputs (maintained command). I.e.
the board recognises the level (for example, if STOP is pressed with maintained OPEN, when
STOP is released, the automation continues to open).
If 03 is disabled, the board commands a movement only in response to a change in the input.
Y = level recognition
no = status change recognition
04
Activation of DEAD MAN opening (command kept pressed). Releasing the OPEN command
stops operation
Y = enabled
no = disabled
05
If you enable this function, an OPEN command during opening stops the movement.
If parameter 06 = no the system is ready for opening.
If parameter 06 = Y the system is ready for closing.
Y = stop movement during ope-
ning
no = disabled
06
If you enable this function, an OPEN command during opening reverses movement.
If parameters 05 and 06 = no, the OPEN command has no effect during opening.
Y = reverse movement during
opening
no = disabled
07
If you enable this function, an OPEN command during a pause stops the movement.
If parameters 07 and 08 = no, the OPEN command reloads the pause time.
Y = stop movement during pause
no = disabled
08
If you enable this function, an OPEN command during the pause closes the automation.
If parameters 07 and 08 = no, the OPEN command reloads the pause time.
Y = close in pause
no = disabled
09
If you enable this function, an OPEN command during closing stops the operation, otherwise
it reverses the movement.
Y = stop
no = reverse
10
DEAD MAN closing enable (command kept pressed). Releasing the CLOSE command
stops the movement.
Y = enabled
no = disabled
11
If you enable this function, a CLOSE command has priority over OPEN, otherwise OPEN has
priority over CLOSE.
Y = enabled
no = disabled
12
If you enable this function, a CLOSE command closes the automation when released. The
unit remains in closing pre-flashing as long as CLOSE is enabled.
Y = close when released
no = close immediately
13
If you enable this function, a CLOSE command during opening stops operation, otherwise
the CLOSE command causes the automation to reverse immediately or at the end of opening
(see also parameter 14)
Y = CLOSE stops movement
no = CLOSE reverses movement
14
If you enable this function, and if parameter 13 = no, the CLOSE command closes the auto-
mation immediately at the end of the opening cycle (memorises the CLOSE). If parameters
13 and 14 = no, CLOSE causes the automation to close immediately.
Y = close at the end of opening
no = close immediately
15
If you enable this function when the system is stopped by a STOP command, a subsequent
OPEN command causes the automation to move in the opposite direction. If parameter
15 = no it always closes.
Y = move in the opposite direction
no = always close
16
If you enable this function, during closing, the CLOSING SAFETIES stop movement and
allow it to resume once they are released, otherwise it immediately reverses in opening.
Y = close when released
no = reverse immediately
17
If you enable this function, the SAFETIES IN CLOSING close the automation when released
(also see parameter 18).
Y = close when FSW is released
no = disabled
18
If you enable this function, and if parameter 17 = Y, the unit waits for the opening cycle to
end before carrying out the closing command issued by the SAFETIES IN CLOSING.
Y = close at the end of opening
no = disabled